EasyManua.ls Logo

PTI security systems APEX - Using Extended Door Controls

PTI security systems APEX
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Using Extended Door Controls
The extended door controls function allows comprehensive access
management. The controls are normally used with an entrance
door, but can be used for a gate or other access device. Extended
door controls use four connections:
Input 1
door alarm contact
Input 2
request to exit device
Relay 1
trigger the door strike
Relay 2
activate a door holder
Open the Door
Operating this function requires a door equipped with a door strike
and a door alarm contact.
The door strike is connected to Relay 1.
The door alarm switch will be connected to Input 1.
The APEX activates Relay 1 for the Door Strike Time
entered during setup programming. This allows the APEX
device to activate the door from a request to exit device.
Relay 1 activates the door strike when a valid access command
is sent from the controller.
This is the only case where the hold time for Relay 1 is not
determined by the controller. Instead it is set by the Door
Strike Time parameter Setup Function.
Once the door strike is activated, the door can be opened.
When the extended door control function is enabled,
other functions for these inputs are disabled.
APEX Access Device
30
114A3863.E rev. 7-2017