Place generator on a level surface.
Remove screws and then remove the outer casing cover.
CAUTION!
generator. Always check oil level before each operation.
ASSEMBLY
Be sure to replace dipstick and securely tighten before attempting to start the engine.
Insert a funnel into the crankcase dipstick hole and carefully add the specified amount of 4-Cycle engine oil (SAE 10W-
30) to empty reservoir until or oil reaches the outer edge of the oil fill hole (crankcase dipstick hole).
To check oil, set generator on a level surface, wipe dipstick clean, then reinsert dipstick without re-threading.
Remove the crankcase dipstick.
Recommended Oil: SAE 10W-30
Oil Capacity: 0.35L (11.8oz)
Adding / Check ing Engine O il