Gasoline to LPG/NG
IMPORTANT: Load capacity is reduced when running on LPG/NG. Make
sure the generator can supply enough (running) and surge (starting)
watts for the items you are powering before switching to LPG/NG.
1. Turn the LPG tank valve(natural gas supply line valve) to the fully
open position.
2. Turn the fuel selector switch to LPG/NG operation.
LPG/NG to Gasoline
1. Turn the fuel selector switch to gasoline operation.
2. Turn the LPG tank valve(natural gas supply line valve) to the fully
closed position.
NOTE: When switching to LPG/NG operation the engine may run rough
for a few seconds while it purges gasoline from the carburetor.
Operation
6. Choose the starting method
Recoil Start: Firmly grasp and pull the recoil handle slowly until you
feel resistance, let it retract then pull swiftly.
Push Button Start: Press the start button for 1-3 seconds, then
release, to start the generator.
Remote Start: Press the START button on the remote FOB for 1
second, then release, to start the generator.
Key Fob Activation Light
START Button
STOP Button
7. Plug in devices.
DANGERDANGER
WARNING
Fire and explosion hazard. Always turn the propane tank valve to
the fully closed position if not running the generator on propane.
When using the generator with propane, make sure there is no
possible ignition source close to the generator.
If the engine stops when switching fuel sources, disconnect all loads
then restart the unit on the fuel source of choice.
Parallel Operation
The parallel connection ports allow you to connect two generators to
increase the total available electrical power. Follow the instructions
included with your parallel connection kit for proper installation and
operation.
Overload Indicator
Note: The OVERLOAD light may turn on for a few seconds as a large
device starts. This is normal for loads approaching the capacity of this
generator.
1.The total combined load through the outlets on the generator must
not exceed the running power of the unit.