EasyManua.ls Logo

Pulsar PGD105TiSCO - Maintenance; Air Filter Element Maintenance; Spark Arrestor Maintenance; Spark Plug Maintenance

Pulsar PGD105TiSCO
25 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19
Maintenance
Air Filter Element Maintenance
1. Loosen screws and remove the Air Filter Access Panel on the left
side of the generator.
Access
Panel
2. Unsnap the Air Filter Cover Clip and remove Air Filter Cover.
See the gure below.
3. Remove Air Filter.
Spark Arrestor Maintenance
WARNING
WARNING
TO PREVENT SERIOUS INJURY AND FIRE:
Operate only with proper spark arrestor installed
The operation of this equipment may create sparks that can start
res around dry vegetation. A spark arrestor may be required. The
operator should contact local re agencies for laws or regulations
relating to re prevention requirements.
1. Allow the generator to cool completely.
2. Remove the Screws from the back of the generator.
3. Remove the Tail Pipe and Spark Arrestor.
4. Clean the Spark Arrestor using a wire brush (sold separately).
Replace the arrestor if damaged.
TO PREVENT SERIOUS INJURY FROM ACCIDENTAL BRUSH FIRE,
secure Spark Arrestor back in place immediately after cleaning
and before further operation.
1. Loosen two screws and remove the Access Panel on the left of the
generator.
Spark Plug Maintenance
Access
Panel
Housing
Air Filter
Air Filter
Cover
Clip (not shown)
2. Disconnect Spark Plug Cap from the end of plug. Clean out debris
from around Spark Plug.
Spark Plug
Spark Plug
Cap
3. Using the Spark Plug Wrench, remove the Spark Plug.
4. Inspect the Spark Plug: If the electrode is oily, clean it using a
clean, dry rag. If the electrode has deposits on it, clean it with a
brass wire brush. If the white insulator is cracked or chipped,
replace the spark plug.
Operator Position
Operator Position

Related product manuals