24
When charging a large capacity battery or totally discharged battery, 
excessive current may force the DC breaker to turn off.
In such cases, use a battery charger to charge a large battery with 
AC output.
Battery defects may cause the DC breaker to trip. Check the battery 
before resetting the DC breaker.
DC APPLICATION
The DC terminal is used for trickle charging 12 volt batteries or low 
amperage drawing DC tools or appliances. It provides 12V - 8.3A
(100W) of maximum power. 
Connection of Cable
Connect positive terminal (red) on generator to positive (+) terminal 
on battery.
Connect negative terminal (black) on generator to negative (-) terminal 
on battery.
SAFETY PRECAUTIONS WHILE CHARGING A BATTERY
WARNING
An explosive hydrogen gas is discharged through 
vent holes in the battery during the charging process. 
Do not allow spark or open ame around the 
generator or battery during the charging process.
Battery Electrolyte uid is poisonous and dangerous, and can burn 
eyes and clothing. Be careful to avoid contact. If contact occurs, 
wash the affected area immediately with large quantities of water 
and consult a doctor for treatment.
operation