EasyManua.ls Logo

Pylontech Force-H1-V2

Pylontech Force-H1-V2
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
4
Buzzer rings continue
Relay adhesion or failure.
Completely disconnect
battery system with any
DC source then make a
restart. If problem
remain, then swap the
controller.
5
Status LED solid
orange. Battery module
LED blue solid.
Communication lost with inverter
Check the
communication cable
PIN and wiring whether
is correctly.
Over current protection.
Check DC side. And wait
until BMS release
protection.
Controller failure.
Use debug tool to
further analysis or
change the controller
module. Or use debug
tool.
6
Status LED solid
orange. Battery module
exists LED in orange
solid
Over/ under temperature
protection.
Check environment
temperature. And wait
BMS release.
Over voltage protection.
Check DC charge voltage
setting or wait BMS
release.
Under voltage protection.
Use black start function,
and then charge the
system.
Battery module BMS failure
Use debug tool to
further analysis or
change the battery
module.
7
All LED blue but no
output.
Fuse fusing
Change the controller
module
8
Other failure
Cell failure or electrical board
failure. Or failure need debug tool
for further debug.
Can’t find out failure
point or can’t check.
Please contact with
distributor or Pylontech.
Once a certain failure detected following the trouble shooting steps, shut down the battery string
first before replacement to avoid further over discharge to the system due to the self-
consumption.

Related product manuals