Operating the System
18
1.PROGRAM AUTO
2.PROGRAM S-AUTO
3.PROGRAM MANUAL
2. Select the desired mode you want to program and follow the instructions
below according to your selection.
IMPORTANT: Note that there is no correlation between the events with the same
number belonging to different modes. For example, you might choose to program
RCUs 1, 3, 5 and 8 in Group 1 in Event 1 in Manual mode; RCUs 4, 12 and 15 in
Group 1 in Event 1 in Semi-Automatic mode; and RCUs 4-13, 15 and 16 in Group 1
in Event 1 in Automatic Mode. When performing an event, the TU may send firing
commands only to the RCUs which have been programmed for the specific event.
1. PROGRAM AUTO
If you want to program the automatic mode, select PROGRAM AUTO in the
PROGRAM EVENT screen. The following screen will be displayed:
GROUP 1 RCU 01 +
OLD NEW
00 -MIN- 00
00.0 -SEC- 00.0
Choose the desired values for GROUP, RCU and Present (+/–).
For each RCU, input the minutes, seconds and tens of seconds (in intervals of 2) as
separate values. The new values of the minutes, seconds and tens of seconds are
inputted, while the old values are displayed as reference. For each PRESENT (+) unit
in a given group, the appropriate Command Key LED will go on green.
When finished, press Esc twice to return to the EVENTS CONTROL screen.
2. PROGRAM S-AUTO
If you want to program the semi-automatic mode, select PROGRAM S-AUTO in the
PROGRAM EVENT screen. The following screen will be displayed:
GROUP 1
RCU 01
PRESENT +
NUMBER 01
Choose the desired values for GROUP, RCU, Present (+/–) and NUMBER.
For each PRESENT (+) unit in a given group, the appropriate Command Key LED
will go on green. In Semi-Automatic Operation, the NUMBER in the above screen
stands for the order of activation of each RCU in the semi-automatic sequence.
Options:
GROUP: 1 to 8
RCU: 01 to 16
PRESENT: + or –
umber: 1 to 128
Options:
GROUP: 1 to 8
RCU: 01 to 16
PRESENT: + or –
Min: 0 to 99