EN50131-6:2008 Rated Output
In accordance with EN50131-6:2008, the EURO standby times and effective output currents depend on the
Security Grade of the system and how 230V mains missing fault is signalled to the Alarm Receiving Centre.
Power supplies are rated in accordance with the requirements of EN50131-6, which are related to the maximum
battery size that can be accommodated in the housing and vary according to the grade of the system in which
they are installed, as per the following table:
Electrical Capability EN50131-6 Rating. Maximum Load
Example Battery Model Grade 2 Grade 3
Yuasa NP7-12 0.5A 0.3A
Yuasa NP17-12 1.2A 0.7A
EN50131-1:2006+A1:2009 (30 hrs if notified to an ARC) for 17Ah battery = 477mA (Grade 3).
EN50131-1:2006+A1:2009 (60 hrs if not notified to an ARC) for 17Ah battery = 193mA (Grade 3).
EURO 46 PCB Current Consumption Environmental
Quiescent 80mA Operational -10°C to +40°C, Certified
User Code and Tag Guessing Storage -20°C to +60°C
4-digit codes 10,000 Humidity 75%
6-digit codes 100,000 Dimensions
Disallowed codes None
EURO 46L
EURO 46S
390 x 305 x 100mm
Weight: 11.5kg inc battery
250 x 297 x 82mm
Weight: 4.8kg inc battery
All codes 16
12
According to EN50131-3:2009 Annex B EURO 46 Printed Circuit Board 170 x 90 x 30mm
According to spec of manufacturer of RFID
components used
EN50131 Grading
EURO 46S = Grade 2. EURO 46L = Grade 3
The below table is specifies ATS (Alarm Transmission System) performance criteria in
accordance with the requirements of EN50136-1-1.
Notification Equipment
Grade 2 Criteria
Option A Option B Option C Option D
Remotely powered
external sounder
2 Optional Optional Optional
Self-powered external
sounder
Optional 1 Optional Optional
Main Communication
Path (ATS)
ATS 2 ATS 2 ATS 2 ATS 3
Second Communication
Path (ATS)
Optional Optional ATS 1 Optional
Notification Equipment
Grade 3 Criteria
Option A Option B Option C Option D
Remotely powered
external sounder
2 Optional Optional Optional
Self-powered external
sounder
Optional 1 Optional Optional
Main Communication
Path (ATS)
ATS 4 ATS 4 ATS 4 ATS 5
Second Communication
Path (ATS)
Optional Optional ATS 3 Optional
When used with a supervised premises transceiver, options 'Grade 3 Option D' is supported. The use of
the Digi Modem restricts the options up to 'Grade 2 Option B'.