7.2 Connecting The Internal Tag Reader (EURO-PROXI)
The Internal Tag Reader can have 2 inputs connected. It can be used
as a set, unset, entry control or an access control device.
NOTE: See the reader installation manual for the LED and button
explanations.
NOTE: The total number of readers that can be installed on the
EURO 46 is 5. The readers are installed on the same bus as the
keypads.
7.2.1 Technical Specification
EURO-PROXI (Internal Tag Reader)
Input Voltage: 12VDC (9-15V DC range)
Supply Current: <30mA Quiescent. <90mA Maximum
Inputs: Programmable. 2 inputs; DEOL
Input EOL Fixed Resistor
Values:
Alarm=4K7 / Tamper=2K2
Normal: 1k4 to 2k9
Burglary Alarm:4k2 to 7k8
Tamper: <1k4 or >22k
Shared Outputs: Switched negative 150mA (Max)
Colour and Casing: White 3mm ABS
Indication: LEDs (Alert, Alarm, Fault, Tamper, Disarmed)
Temperature: Storage:-20°C to 60°C
Certified: -10°C to 40°C
Nominal: -20°C to 60°C
Dimensions (H x W x D): 97 x 40 x 23mm
Front and rear tamper protected
NOTE: If the EURO-PROXI (Internal Tag Reader) is programmed as a 'Set/Unset' device, 2 inputs are enabled. If
the EURO-PROXI is programmed as 'Entry Control' or 'Access Control' only 1 input is enabled.
7.2.2 Addressing the Internal Tag Reader (From the Reader)
NOTE: The addressing is done by adding the relevant numbers on the dip switches:
For example: Dip switch 1 and 2 are only ON = Address 3.
Dip switch 1 and 16 are only ON = Address 17 etc.