EURO 46 Installation Manual
Page: 19
7. Connecting The EURO Peripherals
7.1 Connecting The LCD Keypad (EURO-LCD)
The EURO-LCD keypad is used for programming
and user operation.
The EURO 46 can have up to 6 x EURO-LCD
keypads installed.
NOTE: See the keypad installation manual for
the LED and button explanations.
7.1.1 Technical Specification
EURO-LCD (Keypad)
Supply Voltage: 13.8VDC (9-16VDC Range)
Current: Min Brightness: 25mA
Current: Max Brightness: 45mA (in alarm: 55mA)
Inputs 1 & 2: Programmable, DEOL, Mask/Fault (Grade 3)
Input EOL Resistor Values 1k / 1k DEOL Range 4k7 / 2k2 DEOL Range 4k7 / 4k7 DEOL Range
Normal 0k5 to 1k4 1k4 to 2k9 3k7 to 8k3
Burglary Alarm 1k5 to 5k9 4k2 to 7k8 8k4 to 10k2
Fault 6k to 8k1 8k to 11k3 10k3 to 14k9
Masking (6k8) 8k2 to 17k 11k6 to 22k 15k to 22k
PGM: 100mA
PGM Normal State: Floating
PGM Active State: 0V
Dimensions: 139 x 127 x 29mm
EN50131 Certified: Grade 3
Colour and Casing: White 3mm ABS
Indication: LEDs (Alert, Alarm, Fault, Tamper, Disarmed)
Temperature Storage: -10°C to +50°C
Certified: -10°C to +50°C
Nominal: -10°C to +40°C
Front and rear tamper protected
7.1.2 Addressing The EURO-LCD Keypad
Addressing
Hold the key for more than 5 seconds.
'SECURITY CODE' will be displayed. Enter '2000'

Table of Contents