Matrix 424, 832, 832+ Installation Manual
RINS918-6 Page 31
2.12.5 Zone Doubling to Matrix
NOTE: Up to 64 zones can be programmed when using Zone Doubling on MX 832/832+
The Zone Doubling Map:
Control Panel: Zones 1-8 / Zones 17-24
Plug On Expander: Zones 9-16 / Zones 25-32
RIX1: Zones 33-40 / Zones 49-56
RIX2: Zones 41-48 / Zones 57-64
Spare
A
LARM
Magnetic
Contact
Zone 1 (n)
SUPPLY
ALARM TAMPER
PIR
Detector
Zone 2 (n)
+AU
X
-
SUPPLY
ALARM TAMPER
PIR
Detector
Zone 17 (n+16)
+AU
X
-
MATRIX 832 PCB
2
K
2
4
K
7
4
K
7
4
K
7
Connection of several detectors to one zone
SUPPLY
ALARM TAMPER
PIR
Detector
Zone 18 (n+16)
+AU
X
-
2
K
2
4
K
7
Spare
A
LARM
Magnetic
Contact
SUPPLY
ALARM TAMPER
PIR
Detector
+AU
X
-
SUPPLY
ALARM TAMPER
PIR
Detector
+AU
X
-
SUPPLY
ALARM TAMPER
PIR
Detector
+AU
X
-
4
K
7
2
K
2
Is the first
in the zone
Is the last
in the zone
Zone 1 (n)
4
K
7
Zone 17 (n+16)

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals