EasyManua.ls Logo

Quantum Data 802BT - Page 146

Quantum Data 802BT
744 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
136 Chapter 8 Analyzing Digital Sources and Cables
To set delta error patch testing parameters:
1. Using a terminal emulator, establish a terminal connection with the generator. Refer to
Setting up a terminal connection with the generator” on page 14.
2. Enter the following commands to configure the generator to output a digital signal
(HDMI or DVI):
SROP 2 4
This removes analog friendly mode and configures the generator to output either a DVI
or HDMI signal depending on the interface hardware the generator is equipped with
(DVI or HDMI).
3. (optional) Enter the following commands to set the status display mode:
SROP 8
4. Connect the HDMI/DVI transmit device to the HDMI/DVI Rx connector on the generator.
5. Connect an HDMI/DVI display to the HDMI/DVI Tx connector on the generator.
6. Enter the following commands to load a suitable format for the display under test.
FMTL DMT0660 // loads the DMT0660 format for testing
FMTU // applies the DMT0660 format to the generator
7. Enter the following commands to load a suitable static image.
IMGL FLAT // loads the static image for testing
IMGU // applies the image to the generator
8. Enter the following commands to configure the delta patch parameters.
9.
PDSX 128 // sets patch starting at x-pixel 128
PDSY 256 // sets patch starting at y-pixel 256
PDSH 64 // sets patch height at 64 pixel
PDSW 96 // sets patch width at 90 pixels
10. Enter the following commands to run the delta patch test.
PDAU // captures patch of image
ANIG 1 // enables analyzer images
IMGL DeltaErr // loads the DeltaErr image
IMGU // activates the image in the generator

Table of Contents