Video Test Generator User Guide 225
ANIG
ANalyzer Image Gate
Class DVI signal analyzer
Description Activates or deactivates the FormatRx and DeltaErr analyzer images.
Command syntax ANIG gate
gate
0 = analyzer images are not activated
1 = analyzer images are activated
Query syntax ANIG?
Query response 0 or 1
Example
ANIG 1 // activates analyzer images
IMGL FormatRx; IMGU //outputs FormatRx image