Video Test Generator User Guide 233
ASGG
Analog Sync on Green Gating
Class (Obsolete) Format parameter
Description Enables and disables adding composite sync to the green analog video outputs when
analog sync is selected (see SSST command) and an analog video signal is being
generated (see AVST command). The ASGG? query returns the current setting of ASGG.
See the ASSG command description for information on simultaneously controlling red,
green and green sync gating.
Command syntax ASGG mode
mode
0 = OFF
1 = ON
Query syntax ASGG?
Query response mode
Other required
commands
The FMTU command instructs the generator to use the new setting. The ALLU command
updates hardware to the new setting and redraws the test image.
Example
ASGG 1 // Enable comp sync on green in buffer
FMTU // Update hardware to current buffer contents