464 Appendix A Command Reference
PCPG
Pixel Clock Pulse Gate
Class Format parameter settings
Description Enables and disables the pixel clock pulse output on generators that have a pixel clock
output available. The PCPG? query returns the current setting of PCPG.
Command syntax PCPG mode
mode
0 = OFF
1 = ON
Query syntax PCPG?
Query response mode
Other required
commands
FMTU or ALLU
Example
PCPG 1 // Enable pixel clk output in buffer
FMTU // Update hardware with format data