Specifications
QuantumLTO-8 HH SAS User’s Guide 21
Power specifications
Other specifications
Environmental
specifications
Power Measurements Drive
AC line current 100 to 240 Vac
Line frequency 50 to 60 Hz, auto-ranging
Line current at 100 Vac 0.48 A
Line current at 240 Vac 0.20 A
Specification Measurement
Maximum altitude for operating and storage 3048 m (10,000 ft)
Maximum altitude for shipping 12192 m (40,000 ft)
Environmental Factor
Measurement
Operating Storage Shipping
Tem pe ra tur e 10 to 38°C
(50 to 100°F)
-40 to 60°C
(-40 to 140°F)
-40 to 60°C
(-40 to 140°F)
Relative humidity (non-
condensing)
20 to
80% 10 to 90% 10 to 90%
Wet bulb temperature
(maxim
um)
26°C (78.8°F) Non-condensing Non-condensing

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quantum LTO-8 HH SAS and is the answer not in the manual?

Quantum LTO-8 HH SAS Specifications

General IconGeneral
Native Capacity12TB
Compressed Capacity30TB
Native Data Transfer Rate300 MB/s
Buffer Size1GB
MTBF250, 000 hours
Media TypeLTO Ultrium 8
InterfaceSAS
Compressed Data Transfer Rate750 MB/s
EncryptionAES 256-bit
Backward CompatibilityLTO-7, LTO-6
CompatibilityLTO-8