Chapter 3: System Specifications
Electrical Specifications
52 Scalar i6000 Planning Guide
Table 3 Electrical
Specifications for Control and
Expansion Modules (Not
including HDEMs)
Location
Voltage
(Single Phase,
50 - 60 Hz)
Required
Protective
Service
Delivered Power
Connector
Part Number AMPs
North America 110 30 NEMA L5 - 30 9-01488-03 30
North America 208 30
NEMA L6 - 30
a
9-02919-01 30
North America 208 20 NEMA L6-20 9-02918-01 20
North America 208 15
NEMA L6 - 15
9-01488-04 15
International 240 16
IEC60309 2P+E
d
9-02292-01
20
b
or 16
c
For HDEM:
North America 110 20 NEMA 5-20 9-02947-01 20
International 240 16
IEC 60309
d
1-03260-02
20
b
or 16
c
North America 110 20 NEMA L5-20 9-02949-01 20
North America 208 20
NEMA L6-20
e
1-03260-04
20
International 240 16 CEE 7/7
EUROPEAN
SHUKO
9-02951-01 16
a. For North America, the NEMA L6 - 30 power cord ships by default.
b. 20 amps in North America
c. 16 amps international.
d. For international, the IEC60309 Power Cord ships by default.
e. For North America, the NEMA L6-20 Power Cord ships by default.