EasyManua.ls Logo

Queclink GV200 - Digital Output

Queclink GV200
27 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GV200 User Manual
3.3.11. Digital Output
The outputs are Open-Drain type with no internal pull-up resistor which also be used to
control a relay. It means that the user has to connect a pull-up resistor or a relay coil between
the output pin and any positive voltage (32V max.) to generate a correct output. Each output
can drive a continuous current of 0.2A.
The electrical conditions are:
Table 12: Electrical conditions of digital outputs
Logical State Electrical State
Enable <1.5V, drive current is 0.2A
Disable Open or the pull-up voltage (max 32V)
Digital outputs are used for cutting/restoring GND. The example connections are:
Figure 15: The example connection to drive a LED