EasyManuals Logo
Home>Quectel>Control Unit>SC206E Series

Quectel SC206E Series User Manual

Quectel SC206E Series
116 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
Smart Module Series
SC206E_Series_Hardware_Design 55 / 115
A reference circuit for the LCM interface is shown below.
DSI_CLK_P
LEDA
NC
LEDK
LPTE
NC (SDA-TP)
VIO18
NC (VTP-TP)
DSI_LN3_P
LCD_TE
LCD_RST
DSI_LN3_N
DSI_LN2_P
_CLK_N
DSI_LN2_N
RESET
LCD_ID
NC (SCL-TP)
NC (RST-TP)
NC (EINT-TP)
GND
VCC28
GND
MIPI_TDP3
MIPI_TDN3
GND
MIPI_TDP2
MIPI_TDN2
GND
MIPI_TDP1
MIPI_TDN1
GND
LDO15A_1V8
LCM _ LED+
LCM _LED-
1
2
3
4
5
6
7
8
9
10
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
MIPI_TDP0
MIPI_TDN0
GND
MIPI_TCP
MIPI_TCN
29
28
30
3
4
5
6
3
4
5
6
3
4
5
6
3
4
5
6
DSI_LN1_N
DSI_LN1_P
DSI_LN0_N
DSI_LN0_P
1
2
3
4
5
6
11
1
2
1
2
1
2
1
2
100 nF4.7 μF
1 μF
Module
LCM
FL1
FL2
FL3
FL4
FL5
EMI filter
C3
C2C1
NC
GND
GND
GND
GND
ADC
31
32
33
34
DSI
GND
LDO_IOVDD
NM
LCM_2V8
OUT
GND
IN
EN
LDO
VPH_PWR
GPIO
1 μF
C4
Figure 19: Reference Circuit Design for LCM Interface
MIPI are high-speed signal lines. It is recommended to add common-mode filters in series near the LCM
connector, to improve protection against electromagnetic radiation interference.
DSI_LN2_P
59
AO
LCD MIPI lane 2 data (+)
-
DSI_LN3_N
60
AO
LCD MIPI lane 3 data (-)
-
DSI_LN3_P
61
AO
LCD MIPI lane 3 data (+)
-
PWM
29
DO
PWM output
1.8 V power domain.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Quectel SC206E Series and is the answer not in the manual?

Quectel SC206E Series Specifications

General IconGeneral
BrandQuectel
ModelSC206E Series
CategoryControl Unit
LanguageEnglish

Related product manuals