Ⅳ. Parameter setting and operation
4.4.1.3 Set Initial Speed
1. Init Speed: it is the rotate speed of motor and the setting range is 10~20mm/s.
2. Setting method: press“←”or“→”key to move the cursor and press “Z” or “Z” key to adjust the digit.
3. After setting, press “ENT” key to save and enter “Z Accr Speed” setting interface.
4.4.1.4 Acceleration Setting of Z-axis (Z Accr Speed)
1. The setting range of “Z Accr Speed” is 1~6000mm/ss.
2. Setting method: press“←”or“→”key to move the cursor and press “Z” or “Z” key to adjust the digit.
3. After setting, press“ENT”key to save and enter “Z Max Speed” setting interface.
4.4.1.5 Set Z Max Speed
1. The setting range of Z Max speed is 1~800mm/s. The setting method is same with “Z Accr speed”.
2. After setting, press“ENT”key to save and enter “Work Point” setting inteface.
4.4.1.6 Set Work Point
1. Work point set: Press “ Z ”or “ Z ” to set work point coordinate and the range is 0~100mm.
2. L means the current moving speed is low. Change the moving speed by pressing “PG/CLEAN”key. And
the moving speed can be changed as L (low speed)-H (high speed)-M (middle speed).
3. After setting, press“ENT” key to save the parameters and enter the 1
st