25
Quicksilver 755PH — System & Component Overview and Operaon
water through the pump. To clean the pump strainer, depress the lock tabs on both sides of the pump
and li the pump motor.
If water does not come out of the discharge hose:
1. Remove the motor module to see if the impeller rotates with the power on.
2. Remove any debris that may have accumulated in the nozzle secon or strainer base.
3. Check hose and connecon on hull side for debris and proper connecons.
Check the funcon of all bilge pumps at regular intervals.
Clear pump inlet from debris.
The bilge pumping system is not designed for damage
control.
Typical Bilge Pump System
Bilge pump
Bilge pump hose
Thru hull
5. Livewell System
Your boat is equipped with a 63 liter livewell which is located on the a port side of the boat. The
livewell is used to keep baiish alive by circulang seawater through the tank.
Livewell Operaon
Before operang the system, make sure that the livewell / raw water pickup valve and the ow
control valve are in the open posion. The livewell / raw water pickup valve can be accessed through
the motorwell access plate, while the ow control valve is located on the port a access tub.
The ow of water into the livewell can be controlled at two dierent points. First, the ow control
valve, allows you to control the ow of water into the livewell. If you turn the handle clockwise 90
degrees, the ow of water into the livewell will stop. Next, you can adjust the ow at the aerator
spray head. To increase the ow of water, turn the spray head counterclockwise. To decrease the
ow, turn the spray head clockwise.
To ll the livewell, press the switch marked “LIVEWELL” on the baery switch panel located on the
port a access tub. The livewell overow drain, located on the forward wall of the livewell, allows
excess water to ow overboard. You can regulate the amount of water in the livewell by inserng a
drain plug, thus raising the level of water to the overow drain.
Maintenance
Maintenance of the livewell system will require you to check the ngs and hoses to make sure that