Instruction Book
9828 0934 73 71
Text on figure
(1)
Service
(2)
Overview
(3)
Service plan
(4)
Next service
(5)
History
Scroll through the items to select the desired item and press the Enter key to see the details as
explained below.
Overview
Text on figure
(1)
Overview
(2)
Running Hours (green)
(3)
Real Time hours (blue)
Example for service level (A):
The figures at the left are the programmed service intervals. For Service interval A, the programmed
number of running hours is 4000 hours (upper row, green) and the programmed number of real time
hours is 4380 hours, which corresponds to six months (second row, blue). This means that the controller
will launch a service warning when either 4000 running hours or 4380 real hours are reached, whichever
comes first. Note that the real time hours counter keeps counting, also when the controller is not powered.
The figures within the bars are the number of hours to go till the next service intervention. In the example
above, the dryer was just started up, which means it still has 4000 running hours or 4337 hours to go
before the next Service intervention.