1. Rada Pulse Control Box
Material: Plastic sealed to IP54.
Voltage: 230 V AC, 50/60 Hz.
Transformer: 230 V AC/12 V AC.
Rating: 120 VA.
Main Fuse: T 2.5 A H 250 V
(Important! Use only Rada Approved Fuse, Part No. 422.84)
10 x Inputs suitable for Pulse Sensors.
10 x Solenoid Outputs, 12 V AC SELV (5 fuses) - fused at 2.5 A for each pair.
Door Switch Input (normally closed)
Disable Switch Input (normally open)
Disinfection Enable Input
3 x Auxiliary Outputs, 12V AC SELV (1 fuse) - fused at 400 mA, for connection to
Rada Pulse Relay Box:
Fan Output•
Light Output•
Pump Output•
1 x Disinfection Valve Output
Ambient Temperature Range: 0 - 40°C.
Maximum Humidity: 80% at 25°C.
Type of action: Type 1.
Suitable for continuous use.
Software/Firmware: Class A control function.
2. Rada Pulse Sensors
2.1 Rada Pulse 120/122 Sensors
Material: Plastic shell, Finish: Chrome plated.
3 m of 2 core sheathed cable with connections sealed into the sensor.
Operating voltage: 12 V AC. via the 2 core cable.
Fixing holes for 2 x 6 mm dome headed screws (supplied).
Protection: IP67.
Temperature range: 4 to 70°C.
Activation distance -120 sensor 0 to 50 mm.
-122 sensor 0 to 550 mm.
The distance is dependent on the reectivity of the detected object.
SPECIFICATIONS