EasyManua.ls Logo

rada Pulse Series - Specifications for Rada Pulse System; Rada Pulse Control Box Specifications; Rada Pulse Sensor Specifications

rada Pulse Series
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
16
1. Rada Pulse Control Box
Material: Plastic sealed to IP54.
Voltage: 230 V AC, 50/60 Hz.
Transformer: 230 V AC/12 V AC.
Rating: 120 VA.
Main Fuse: T 2.5 A H 250 V
(Important! Use only Rada Approved Fuse, Part No. 422.84)
10 x Inputs suitable for Pulse Sensors.
10 x Solenoid Outputs, 12 V AC SELV (5 fuses) - fused at 2.5 A for each pair.
Door Switch Input (normally closed)
Disable Switch Input (normally open)
Disinfection Enable Input
3 x Auxiliary Outputs, 12V AC SELV (1 fuse) - fused at 400 mA, for connection to
Rada Pulse Relay Box:
Fan Output
Light Output
Pump Output
1 x Disinfection Valve Output
Ambient Temperature Range: 0 - 40°C.
Maximum Humidity: 80% at 25°C.
Type of action: Type 1.
Suitable for continuous use.
Software/Firmware: Class A control function.
2. Rada Pulse Sensors
2.1 Rada Pulse 120/122 Sensors
Material: Plastic shell, Finish: Chrome plated.
3 m of 2 core sheathed cable with connections sealed into the sensor.
Operating voltage: 12 V AC. via the 2 core cable.
Fixing holes for 2 x 6 mm dome headed screws (supplied).
Protection: IP67.
Temperature range: 4 to 70°C.
Activation distance -120 sensor 0 to 50 mm.
-122 sensor 0 to 550 mm.
The distance is dependent on the reectivity of the detected object.
SPECIFICATIONS

Related product manuals