22
Advanced Programming
Advanced Programming
You can clone your scanner by transferring the programmed data to or from 
another PRO-136 scanner using a connecting cable. You can also upload or 
download programmed data from a PC through wired programming.
Cloning Your Scanner
You can clone all the frequencies in 
your PRO-136 to another PRO-136 or 
PRO-135 using an optional interface 
cable with 1/8-inch phone plugs on 
both ends.
1. Make sure the scanners are turned 
off and then plug the cable into 
each scanner’s PC/IF jack.
2. Turn on both scanners. WirEd and PGM appear.
  PGM
     
            
3. Press T or S on the scanner from which you want to send frequencies. 
This is the “master unit.” The receiving scanner is the “slave unit.”
4. Press ENT/PROGRAM on the master unit to send the data. SEnd and the 
transfer progress are displayed in the master unit. 
BANK0 1 2 3      PGM
     
            
PC/IF Jack