OPTION MAIN TYPE SUB TYPE DIELECTRIC SETTING
M/µs
PVF V V/2
4 IBM TYPE 1
TYPE 2
TYPE 3
TYPE 6
TYPE 9
0.78
0.78
0.62
0.78
0.69
234
234
186
234
207
117
117
93
117
104
5 DATA RG58
RG58U
THICK ETHERNET
THIN ETHERNET
RG11, RG6
0.78
0.66
0.78
0.67
0.82
234
198
234
201
246
117
99
117
101
123