RadioLink Electronic Ltd
www.radiolink.com
2. Telemetry
R8F can return the real-time information such as RSSI, receiver voltage and model battery
voltage.
In order to enjoy this function, please upgrade RC6GS(3-position switch version) with the
firmware RC6GS_RadioLink_bin_1d15_V_6_0_0 downloaded via
http://radiolink.com.cn/doce/Firmwares/RC6GS&R7FG.rar
Or upgrade RC4GS(produced after 2018-01-01) with the firmware
RC4GS_RX_RadioLink_bin_2f50_V_6_0_1 downloaded via
http://radiolink.com.cn/doce/Firmwares/RC4GS&R7FG.rar
2.1 Telemetry of Signal and RSSI
Power on the transmitter and the receiver and complete the binding, signal will be displayed on
the homepage of transmitter. Short press EXIT twice and enter the interface with returned
information including RSSI value.
Warning can be set with a certain low RSSI value after testing by changing distance:
Press EXIT and ENTER simultaneously to enter MENU=>press Inc(+) to highlight “19. ALARM
=>Press ENTER to (dis)activate the warning and set the RSSI warning value.
2.2 Telemetry of model battery and receiver voltage
Besides the return of receiver voltage, model battery voltage (maximum up to 6S lithium
battery) can also be returned in real time. Users can personalize the warning value of low
model battery voltage depending on the actual needs.
Press EXIT and ENTER simultaneously to enter MENU=>press Inc(+) to highlight “19. ALARM
=>Press ENTER to set the model battery voltage warning value.
Normally we set the warning value with the single cell voltage as 3.7V. For example, if it is 3S
lithium battery used in the model car, the warning value should be set as (3.7V*3S=)11.1V.