Trap parameters Appendix F
RADWIN 1000/2000/5000 User ManualVersion 2.5.30p3 F-20
externalAlarmInPort1Alarm 105 major The trap is sent every time an alarm occurs in the External Alarm Input of
port #1. Contains a single parameter which is its description: 1 -
Description: External Alarm 1 - <User Text> - Alarm.
externalAlarmInPort2Alarm 106 major The trap is sent every time an alarm occurs in the External Alarm Input of
port #2. Contains a single parameter which is its description: 1 -
Description: External Alarm 2 - <User Text> - Alarm.
bitFailedAlarm 107 critical The trap is sent in case there is no way to recover from the situation.
Contains two parameters: 1 - Description: ODU power up built in test
failed. Error code is: %n. 2 - %n number.
wrongConfigurationLoadedAlarm 108 major The trap is sent in case there is a way to recover from the situation.
Contains two parameters: 1 - Description: Wrong configuration loaded.
Error code is: %n. 2 - %n number.
lanPort1DisconnectedAlarm 109 major Indicates the LAN port 1 status changed to disconnected. Contains a
single parameter which is its description: 1 - Description: LAN port 1
status changed to disconnected.
lanPort2DisconnectedAlarm 110 major Indicates the LAN port 2 status changed to disconnected. Contains a
single parameter which is its description: 1 - Description: LAN port 2
status changed to disconnected.
mngPortDisconnectedAlarm 111 major Indicates the management port status changed to disconnected.
Contains a single parameter which is its description: 1 - Description:
Management port status changed to disconnected.
externalAlarmInPort3Alarm 112 major The trap is sent every time an alarm occurs in the External Alarm Input of
port #3. Contains a single parameter which is its description: 1 -
Description: External Alarm 3 - <User Text> - Alarm.
externalAlarmInPort4Alarm 113 major The trap is sent every time an alarm occurs in the External Alarm Input of
port #4. Contains a single parameter which is its description: 1 -
Description: External Alarm 4 - <User Text> - Alarm.
swVersionsMismatchFullCompatibilityAlarm 114 warning The trap is sent in case SW versions mismatch with full link functionality.
Contains a single parameter which is its description: 1 - Description:
Software versions mismatch - full link functionality
swVersionsMismatchRestrictedCompatibilityAlarm 115 minor The trap is sent in case SW versions mismatch with restricted link
functionality. Contains a single parameter which is its description: 1 -
Description: Software versions mismatch - restricted link functionality
swVersionsMismatchSoftwareUpgradeRequired 116 major The trap is sent in case SW versions mismatch and SW upgrade is
required. Contains a single parameter which is its description: 1 -
Description: Software versions mismatch - Software upgrade required
swVersionsIncompatible 117 critical The trap is sent in case SW versions are incompatible. Contains a single
parameter which is its description: 1 - Description: SW Versions
incompatible
tdmBackupAlarm 121 major Indicates that the TDM backup link was activated. Contains a single
parameter, which is its description: 1 - Description: TDM backup alarm -
backup link was activated.
linkLockUnautorizedRemoteODU 122 major Indicates that the remote ODU is unautorized. Contains a single
parameter which is its description: 1 - Description: Unauthorized remote
ODU connection rejected.
linkLockUnautorizedODU 123 major Indicates that the ODU is unautorized. Contains a single
parameter which is its description: 1 - Description: Unauthorized ODU
connection rejected.
tdmServiceClear 200 normal Indicates that TDM Service fault is cleared. Contains a single parameter,
which is its description: 1 - Description: TDM Service - Normal.
ethServiceOpened 201 normal Indicates that Ethernet Service has been opened. Contains a single
parameter,3 which is its description: 1 - Description: Ethernet Service has
been opened.
encryptionClear 203 normal Indicates that encryption is OK. Contains a single parameter which is its
description: 1 - Description: Encryption Status - Normal.
Table F-3: MIB Traps (Sheet 3 of 4)
Name ID Severity Description

Table of Contents