FinMDeploymentGuide Release4.5.10 28
TBSMounting SiteInstallation
Verticalpole‐medium
1. Diameter2to3:BeforeraisingtheTBSonthepole,positionthepoleclampasshownin
thefollowingtwofigures.Donotcompletelytightenthebolts:
2. PlacethisassemblyonthepolewhereyouwanttomounttheTBS.Onceitisinplace,
rotatethepoleclampasshown,thentightenbothbolts.
VerticalPole‐thick
1. Diameterlargerthan3:Usewormdriveclamps(notsupplied),threadedthroughtheholes
asshowninFigure 213,orUbolts(notsupplied),fastenedusingtheholesasshownin
Figure 214:
Figure29:Mediumpole:Fastenclampto
baseplate
Figure210:Mediumpole:Donotcom
pletelytightenbolts
Figure211:Mediumpole:R otateclamp Figure212:Mediumpole:tightenbolts