FinMDeploymentGuide Release4.5.10 411
ProjectTab ConfiguringtheRadioNetwork
Figure45:Configurator‐Projecttab,lowertable(VLANoptions)
Figure46:Configurator‐Projecttab,lowertable(Diffservoptions)
Min:SettheminimumstandardprioritylevelthattheQoScategorywillreceive:
InFigure 45(showingvaluesaccordingtotheVLANstandard),RealTimehasa
minimumof6.
InFigure 46(showingvaluesaccordingtotheDiffservstandard),RealTimehasa
minimumof48.
Max:SetthemaximumstandardprioritylevelthattheQoScategorywillreceive.
InFigure 45(showingvaluesaccordingtotheVLANstandard),RealTimehasa
maximumof7.
InFigure 46(sho
wingvaluesaccordingtotheDiffservstandard),RealTimehasa
maximumof63.
3. Downlink%andUplink%:SetthepercentageoftrafficeachQoScategoryistobe
allotted.Thiscanbedifferentforthedownlink(TBS‐>TMU)oruplink(TMU‐>TBS)
direction.Iftrafficofacert
ainQoSlevelismorethanthispercentage,itistreated
asBestEffort.
Youmustmakesuretocoveralltheprioritylevels,otherwisethesystemwill
createerrors.Nowarningwillbe given.
Thepercentagescannotadduptomorethan100,otherwisethesystemwill
createerrors.Nowarningwillbe given.
Ifthepercentagesadduptolessthan100,theunusedprioritywillbedistributed
totheremainingpriorities.