GUI reference
R&S
®
ZNA
333User Manual 1178.6462.02 ─ 20
Driving Port
Allows you to evaluate the influence of the different front side receiver inputs and the
"Preamp. Gain" on page 478 "b1" ("Isolation Amplifier") on the measurement time.
Setting the "Receiver Input" and "Isolation Amplifier" here is equal to activating it in the
"Input/Output tab" on page 621 of the "Port Configuration" dialog or the Power tab of
the "Pwr Bw Avg" softtool, respectively.
In additition, it is possible to specify an external attenuation at the driving port to let the
"Quickset" logic choose the suitable source powers for calibration and measurement.
Receiving Port
For the receiving port, you can activate or deactivate the Reverse Coupler Configura-
tion and the Internal low noise preamplifier. The R&S ZNA immediately calculates the
resulting measurement time and displays it in the Result Settings section.
In additition, it is possible to specify an external attenuation at the receiving port to let
the "Quickset" logic choose the suitable source powers for calibration and measure-
ment.
Det Time Overview
Opens the "Detector Time Overview" dialog, which shows an overview of the resulting
detector times for each step of the calibration and measurement.
Meas softtool