GUI reference
R&S
®
ZNA
427User Manual 1178.6462.02 ─ 20
Comment Added to File
Defines a comment to be added to the exported trace data file.
If empty (←"Delete"), no comment is added.
Remote command:
MMEMory:STORe:TRACe:OPTion:COMMent
5.5.11.3 Select Parameter dialog
The "Select Parameter" dialog provides a selection of measurement results (e.g. S-
parameters) or traces, e.g. for trace import, import of power correction coefficients, limit
line import.
Access: The dialog may be called from several dialogs, for example on pressing
"Open" in the Import Complex Data dialog.
Select All / Deselect All
During trace data import, selects/deselects all traces contained in the opened trace file.
Auto Distribute
Available for trace data import only.
If checked, a selected trace S
ij
is imported as a memory trace for all data traces in the
current recall set that are measuring S
ij
.
Remote command:
MMEMory:LOAD:TRACe:AUTO
5.5.11.4 Select Ports dialog
The "Select Ports" dialog defines the port assignment for the created Touchstone
(*.s<n>p) file.