38
7 Water connection
7 Water connection
The device complies with all relevant regulations
(SVGW, KIWA, WRAS).
7.1 Prerequisites
> The user must supply each device with its
own water tap.
> Rinse the water supply line before connecting
the device to water!
> Water pressure 1.5 - 6bar, 3bar recommend-
ed.
Unit CMP XS due to descaling of the steam generator:
> Drinking water protection for substance class
3 pursuant to EN 1717, such as a CA sys-
tem separator pursuant to EN 14367, must
be installed in the feed line on the tap at the
drinking water network connection point.
> The CA system separator is supplied for NL
and CH, and are available through RATIONAL
using part number 50.01.820 for other Euro-
pean countries.
All other appliances meet the requirements for drinking water pro-
tection pursuant to EN1717 in as-delivered con-
dition.
> Flow rates required for each device (max.):
Appliance size 60 61 62 11 12 21 22
l/min 7 20 25 20 25 25 25
Connect the device to drinking water-quality
water.
Connect a flexible drinking-water connection
hose in accordance with EN 61770 or EN 13618
or of similar quality. Take any necessary safety
precautions with the water tap, such as backflow
preventers or CA system separators.
The water connection hose must comply with
country-specific hygiene standards for drinking
water hoses.

Other manuals for Rational COMBIMASTER

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rational COMBIMASTER and is the answer not in the manual?

Rational COMBIMASTER Specifications

General IconGeneral
BrandRational
ModelCOMBIMASTER
CategoryOven
LanguageEnglish

Related product manuals