EasyManua.ls Logo

Rational iCombi Pro 6-1/1 - Troubleshooting Gas, Hot Air, and Moisture Errors

Rational iCombi Pro 6-1/1
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17 | Inspiration and help
Operating instructions 97 / 112
Error report Cause Cooking possible
Service 32.1 The gas burner is faulty.
Close the shut-off valve on the gas line.
No
Service 32.2 The gas burner is faulty.
Close the shut-off valve on the gas line.
No
Service 32.3 The gas burner is faulty.
Close the shut-off valve on the gas line.
No
Service 33.1 The gas burner is faulty.
Close the shut-off valve on the gas line.
No
Service 33.2 The gas burner is faulty.
Close the shut-off valve on the gas line.
No
Service 33.3 The gas burner is faulty.
Close the shut-off valve on the gas line.
No
Service 34.32 The internal data communication is faulty. Yes
Service 60 The initialisation of the ignition box is
defective.
Switch the unit off and on again. If the
error is still displayed, call your Service
Partner.
17.5.3 Error messages heating hot air
Error report Cause Cooking possible
Service 20.1 The temperature probe is defective. No
Service 28.1 The temperature limit of the steam
generator has been exceeded.
No
Service 28.2 The temperature limit of the cooking
cabinet has been exceeded.
No
Service 34.1 The internal data communication is faulty. No
Service 34.2 The internal data communication is faulty. No
Service 34.4 The internal data communication is faulty. No
Service 42.3 The water supply is faulty. The steam injection is not
available.
Service 42.6 The water supply is faulty. Yes
Service 43.3 The internal water supply is not closing. Only the convection mode is
available at the moment.
17.5.4 Error messages moisture
Error report Cause Cooking possible
Service 20.2 The temperature probe is defective. Yes
Service 20.4 The temperature probe is defective. Yes
Service 30 The humidity measurement is incorrect. Yes
Service 36 The differential pressure sensor is
defective.
Yes
Service 37 The differential pressure sensor is
defective.
Yes
Service 42.2 The water supply is faulty. Yes

Table of Contents