17 | Inspiration and help
98 / 112 Operating instructions
Error report Cause Cooking possible
Service 43.2 The internal water supply is not closing. Only the convection mode is
available at the moment.
17.5.5 Error messages CleanJet
Error report Cause Cooking possible
Service 25 The water quantity required by the
iCareSystem is too low.
Service 26 The ball valve cannot find the open
position.
No
Service 27 The ball valve cannot find the closed
position.
No
Service 34.8 The automatic clean does not work. Yes
Service 43.6 The internal water supply is not closing. Only the convection mode is
available at the moment.
Service 47.1 The waste water pump is defective. Yes
Service 47.2 The waste water pump is defective. Yes
Service 48.1 The circulating pump is defective. Yes
Service 48.2 The circulating pump is defective. Yes
Service 110 An error occurred in the SC pump during
the automatic clean.
No
Service 120 An error occurred in the water level
recognition during the automatic clean.
No
17.5.6 Error messages Care
Error report Cause Cooking possible
Service 40 The quantity of care liquid required by the
iCareSystem is too low.
Yes
Service 42.4 The water supply is faulty. Yes
Service 43.4 The internal water supply is not closing. Only the convection mode is
available at the moment.
Service 49.1 The water supply is faulty. Yes
Service 49.2 The water supply is faulty. Yes
17.5.7 Notification centre
Error report Cause Cooking possible
Service 17 The unit model is incorrect. No
Service 29 The board temperature is too high. No
Service 31.1 The core probe in the cooking cabinet is
defective.
Yes, you cannot use the core
probe.
Service 31.2 The core probe in the cooking cabinet is
defective.
Yes, but you cannot use the
core probe.
Service 34.16 The internal data communication is faulty. Yes
Service 34.64 The internal data communication is faulty. Yes
Service 34.400 The internal data communication is faulty. Yes
Service 41 The steam injection nozzle or the steam
injection pipe has scale.
The steam injection is not
available.