6 | Electrical connection
38 / 56 80.06.562_IM_2-XS_ 2-S_en-INT
3N AC 415 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 15 20 25 2,5
iVario Pro 2-S 22 31 32 4
3 AC 200 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 13 37 40 6
iVario Pro 2-S 19 55 63 10
3 AC 208 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 15 48 50 10
iVario Pro 2-S 23 64 70 16
3 AC 220 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 13 33 40 6
iVario Pro 2-S 19 50 50 10
3 AC 230 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 14 34 40 6
iVario Pro 2-S 21 51 51 10
3 AC 240 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 15 35 35 6
iVario Pro 2-S 22 53 60 10
3 AC 400 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 14 20 20 2,5
iVario Pro 2-S 21 30 32 4
3 AC 415 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 15 20 20 2,5
iVario Pro 2-S 22 31 32 4
3 AC 440 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 13 17 20 3