6 | Electrical connection
80.06.562_IM_2-XS_ 2-S_en-INT 39 / 56
3 AC 440 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario Pro 2-S 19 25 25 4
3 AC 480 V Power kW Amp draw A Fuse A Conductor cross-sec-
tion mm²
iVario 2-XS 15 18 20 2,5
iVario Pro 2-S 22 27 30 4
6.8 Check the function of the socket in the unit
Power ratings for socket in the unit
Standard version without residual current circuit breaker:
By default, the socket in the unit is equipped with a 10 A fuse. The maximum
available power is 2,3 kW.
Version with residual current circuit breaker:

Other manuals for Rational iVario Pro 2-S