6 | Electrical connection
80.06.070_iCombi Pro-iCombi Classic_IM_V01_en-GB 55 / 92
Unit size 6-1/1 GN up to 10-2/1 GN
Unit size 20-1/1 GN, 20-2/1 GN
6.9 Power ratings of different voltage types
Maximum connection voltage
n
Maximum permissible tolerance for input voltage: -15% to +10%.
n
The unit can be used with frequencies of 50 Hz and 60 Hz without making
any technical modifications.
iCombi Pro, iCombi Classic Electric units
Hz Current
consump-
tion (A)
Power (kW) Fuse (A) RCD type
6-2/3 (1 NAC 230 V) 50/60 23.1 5.3 25 F
6-1/1 E (1 NAC 230 V) 50/60 47 10.8 50 F