Chapter 2: Installation
23
Type 1 Drive Units/Stern Drive/Constant Running Pump
Cable Length
(Distribution
panel to Course Computer)
Cable Gauge Copper Area
Up to 3m (10ft) 12 AWG 2.5 mm
Up to 5m (16ft) 10 AWG 4 mm
Up to 7m (23ft) 8 AWG 6 mm
Up to 10m (32ft) 6 AWG 10 mm
Up to 16m (52ft) 4 AWG 16 mm
81004-01
Type 2 Drive Units (12V)
Cable Length
(Distribution
panel to Course Computer)
Cable Gauge Copper Area
Up to 5m (16ft) 8 AWG 6 mm
Up to 7m (23ft) 6 AWG 10 mm
Up to 16m (52ft) 4 AWG 16 mm
81004-02
Type 2 Drive Units (24V)
Cable Length
(Distribution
panel to Course Computer)
Cable Gauge Copper Area
Up to 3m (10ft) 12 AWG 2.5 mm
Up to 5m (16ft) 10 AWG 4 mm
Up to 7m (23ft) 8 AWG 6 mm
Up to 10m (32ft) 6 AWG 10 mm
Up to 16m (52ft) 4 AWG 16 mm
81004-01

Table of Contents