•Amber—warnsofaproblemintheunit.
•R
ed—showsthatthereisanerrorintheunit.
ThenumberoftimestheLEDblinksisacodewhichrepresentstheerrorsorwarningsasshown
intheLEDindicationstatustable.Iftherearemultiplewarningsorerrors,thecodesaregivenin
sequencewitha2secondpausebetweenblinkpatterns.
LEDindicationstatus
LED
colorLEDcodeS
tatusUseraction
Solid
Green
PowerOn
•None(normalpoweruptakes<1
minute.)
Green1
blink
Normal
operation
•None
Amber1
blink
Transducer
discon-
nected
•Ensuretransducercableand
connectionsaresecureandfree
fromdamage.
•Powercycleunittorecover
transducerinformation.
•IfproblempersistscontactRaymarine
technicalsupport.
Amber
2blinks
Nonetwork
detected
•Ensurenetworkispowered.
•Ensurenetworkcableand
connectionsaresecureand
freefromdamage.
•IfproblempersistscontactRaymarine
technicalsupport.
Amber
3blinks
Unit
overheating
•Ensureinstallationenvironmentis
withinrecommendations.
•Unitwillrecoverwhentemperature
fallswithinspecifications.
•IfproblempersistscontactRaymarine
technicalsupport.
Amber
4blinks
*Transducer
overheating
•Ensureinstallationenvironmentis
withinrecommendations.
•Unitwillrecoverwhentemperature
fallswithinspecifications.
•IfproblempersistscontactRaymarine
technicalsupport.
Amber
5blinks
Under
voltage
(<10.2V)
•Ensurepowercableandconnections
aresecureandfreefromdamage.
•Ensurepowersupplycablingis
consistentwithrecommendations.
•IfproblempersistscontactRaymarine
technicalsupport.
Amber
6blinks
Over
voltage
(>34.2V)
•Ensurepowersupplylevelsare
consistentwithrecommendations.
•IfproblempersistscontactRaymarine
technicalsupport.
S ystemchecksandtroubleshooting
75