Amberwarnsofaproblemintheunit.
R
edshowsthatthereisanerrorintheunit.
ThenumberoftimestheLEDblinksisacodewhichrepresentstheerrorsorwarningsasshown
intheLEDindicationstatustable.Iftherearemultiplewarningsorerrors,thecodesaregivenin
sequencewitha2secondpausebetweenblinkpatterns.
LEDindicationstatus
LED
colorLEDcodeS
tatusUseraction
Solid
Green
PowerOn
None(normalpoweruptakes<1
minute.)
Green1
blink
Normal
operation
None
Amber1
blink
Transducer
discon-
nected
Ensuretransducercableand
connectionsaresecureandfree
fromdamage.
Powercycleunittorecover
transducerinformation.
IfproblempersistscontactRaymarine
technicalsupport.
Amber
2blinks
Nonetwork
detected
Ensurenetworkispowered.
Ensurenetworkcableand
connectionsaresecureand
freefromdamage.
IfproblempersistscontactRaymarine
technicalsupport.
Amber
3blinks
Unit
overheating
Ensureinstallationenvironmentis
withinrecommendations.
Unitwillrecoverwhentemperature
fallswithinspecifications.
IfproblempersistscontactRaymarine
technicalsupport.
Amber
4blinks
*Transducer
overheating
Ensureinstallationenvironmentis
withinrecommendations.
Unitwillrecoverwhentemperature
fallswithinspecifications.
IfproblempersistscontactRaymarine
technicalsupport.
Amber
5blinks
Under
voltage
(<10.2V)
Ensurepowercableandconnections
aresecureandfreefromdamage.
Ensurepowersupplycablingis
consistentwithrecommendations.
IfproblempersistscontactRaymarine
technicalsupport.
Amber
6blinks
Over
voltage
(>34.2V)
Ensurepowersupplylevelsare
consistentwithrecommendations.
IfproblempersistscontactRaymarine
technicalsupport.
S ystemchecksandtroubleshooting