10.1Radarpowerconnections
TheCycloneOpenArrayRadarscannermustbepoweredviathesuppliedVCM100Converter
Module.
Important:
Fuses(notsupplied)arerequiredforcircuitprotectionfortheCycloneRadar:
12Vdc
•15Athermalfuseatbreaker(x1)
•20AinlinefuseonREDpowercable(x1)
24Vdc
•8Athermalfuseatbreaker(x1)
•10AinlinefuseonREDpowercable(x1)
1.CycloneOpenArrayRadarscanner
2.Cyclonepowercable(A80653)
3.VCM100powerconverter
4.PowercablefromvesselpowersupplytoVCM100(powercablenotsupplied)
5.Vesselpowersupply
TheCycloneOpenArrayRadarisintendedforuseonvesselDCpowersystemsoperatingat12
or24VoltsDC.
•AllpowerconnectionsmustbemadeviatheVCM100VoltageConverterModule.
•TheradarscannermustNOTbeconnecteddirectlytoabattery.
•TheradarscannermustbeconnecteddirectlytotheVCM100only.
•OnlyoneradarscannermustbeconnectedperVCM100unit.Eachradarscannerinyoursystem
requiresadedicatedVCM100unit.
•ThepowerconnectionbetweentheradarscannerandtheVCM100mustbeviaanofficial
Raymarinepowercable(apowercableissuppliedwiththeradar).
•DoNOTcutandre-joinanypartofthepowercable.Arangeofcablelengthsandcableextensions
isavailableforlongercableruns(refertop.86—Accessories).