10.1Radarpowerconnections
TheCycloneOpenArrayRadarscannermustbepoweredviathesuppliedVCM100Converter
Module.
Important:
Fuses(notsupplied)arerequiredforcircuitprotectionfortheCycloneRadar:
12Vdc
15Athermalfuseatbreaker(x1)
20AinlinefuseonREDpowercable(x1)
24Vdc
8Athermalfuseatbreaker(x1)
10AinlinefuseonREDpowercable(x1)
1.CycloneOpenArrayRadarscanner
2.Cyclonepowercable(A80653)
3.VCM100powerconverter
4.PowercablefromvesselpowersupplytoVCM100(powercablenotsupplied)
5.Vesselpowersupply
TheCycloneOpenArrayRadarisintendedforuseonvesselDCpowersystemsoperatingat12
or24VoltsDC.
AllpowerconnectionsmustbemadeviatheVCM100VoltageConverterModule.
TheradarscannermustNOTbeconnecteddirectlytoabattery.
TheradarscannermustbeconnecteddirectlytotheVCM100only.
OnlyoneradarscannermustbeconnectedperVCM100unit.Eachradarscannerinyoursystem
requiresadedicatedVCM100unit.
ThepowerconnectionbetweentheradarscannerandtheVCM100mustbeviaanofficial
Raymarinepowercable(apowercableissuppliedwiththeradar).
DoNOTcutandre-joinanypartofthepowercable.Arangeofcablelengthsandcableextensions
isavailableforlongercableruns(refertop.86Accessories).