EasyManua.ls Logo

Raymarine CYCLONE - VCM100 Screen (Drain) Wire Extension; Circuit Breaker and Fuse Ratings

Raymarine CYCLONE
92 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VCM100screen(drain)wireextension
Thescreen(drain)wirecanbeextendedforlongercablerunsbetweentheVCM100andyour
vessel'sRFgroundsystem.
Extensionstothescreen(drain)wireshouldusean8mmbraidorAWG10(5.26mm
2
)multi-stranded
cable.
Circuitbreakerandfuseratings
Batteryisolatorswitch,thermalbreaker,andfuseratings.
AllpowerconnectionsbetweentheVCM100anditspowersourcemustbeprotectedbyathermal
circuitbreakerorfuse,fittedclosetothepowerconnection.Theconnectionfromtheoutputofthe
VCM100tothedigitalradardoesnotrequireafuseorcircuitbreaker.
Ifyoudonothaveathermalcircuitbreakerorfuseinyourpowercircuit(fittedtotheDCdistribution
panel,forexample),youMUSTfitanin-linebreakerorfusetothepositivewireofthepowercable.
Thefollowingtableprovidessuitableratingsforbatteryisolatorswitches,circuitbreakers,andfuses.
PowersupplyDevice4kWscanner12kWscanner
Isolatorswitch
30amps(minimum
rating)
30amps(minimum
rating)
Thermalbreaker15amps15amps
12volt
Fuse
20amps20amps
Isolatorswitch
15amps(minimum
rating)
15amps(minimum
rating)
Thermalbreaker
8amps8amps
24volt
Fuse
10amps10amps
Warning:Productgrounding
Beforeapplyingpowertothisproduct,ensureithasbeencorrectlygrounded,in
accordancewiththeinstructionsprovided.
Powerconnections
63

Table of Contents

Related product manuals