EasyManua.ls Logo

Raymarine Element 12 HV - Page 36

Raymarine Element 12 HV
82 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
W aterprooffuseholdercontainingasuitably-ratedinlinefusemustbefitted.
Forsuitablefuserating,referto:
In-linefuseandthermalbreakerratings
.
2
Productpowercable .
3
Drainwireconnectionpoint.
BatteryconnectionscenarioA:
SuitableforavesselwithacommonRFgroundpoint.Inthisscenario ,ifyourproduct’spowercableis
suppliedwithaseparatedrainwirethenitshouldbeconnectedtothevessel’scommongroundpoint.
BatteryconnectionscenarioB:
Suitableforavesselwithoutacommongroundingpoint.Inthiscase,ifyourproduct’spowercableis
suppliedwithaseparatedrainwirethenitshouldbeconnecteddirectlytothebattery’snegative
terminal.
Powercableextension
Ifyouneedtoextendthelengthofthepowercablesuppliedwithyourproduct,ensureyouobserve
thefollowingadvice:
Thepowercableforeachunitinyoursystemshouldberunasaseparate,singlelengthof2-wire
cablefromtheunittothevessel'sbatteryordistributionpanel.
Forpowercableextensions,aminimumwiregaugeof16AWG(1.31mm
2
)isrecommended.For
cablerunslongerthan15meters,youmayneedtoconsiderathickerwiregauge(e.g.14AWG
(2.08mm
2
),or12AWG(3.31mm
2
)).
Animportantrequirementforalllengthsofpowercable(includinganyextension)istoensurethat
thereisacontinuousminimumvoltageattheproduct’spowerconnectorof10.8Vdc,witha
fullyflatbatteryat11Vdc.
Important:
Beawarethatsomeproductsinyoursystem(suchassonarmodules)cancreatevoltagepeak sat
certaintimes,whichmayimpactthevoltageavailabletootherproductsduringthepeaks.
Grounding
Ensurethatyouobserveanyadditionalgroundingadviceprovidedintheproduct’ sdocumentation.
36

Table of Contents

Related product manuals