4.2P
owerconnection
Thepowercablemustbeconnectedtoa12Vdcpowersupply,thiscanbeachievedbyconnecting
directlytoabattery,orviathedistributionpanel.Theproductisprotectedagainstreversepolarity.
1.P ower/NMEA2000cableconnectstotherearofthedisplay.
2.GroundwireconnectstoRFgroundpoint,ifnogroundpointisavailableconnecttothebattery
negative(-)terminal.
3.Positive(Red)wireconnectstobatterypositive(+)terminal.
4.Waterprooffuseholderwith5Ainlinefusemustbefitted(notsupplied).
5.Negativewireconnectstobatterynegative(-)terminal.
Important:T opreventerraticbehaviorandpotentialdataloss,ensuretheproductissuppliedfrom
aseparatebatteryfromthatusedforenginestart.
In-linefuseandthermalbreak erratings
Thefollowingin-linefuseandthermalbreakerratingsapplytoyourproduct:
In-linefuse
ratingThermalbreak errating
5A
3A
Note:
•Thesuitablefuseratingforthethermalbreak erisdependentonthenumberofdevicesyouare
connecting.IfindoubtconsultanauthorizedRaymarinedealer.
•Y ourproduct’spowercablemayhaveanin-linefusefitted,ifnotthenyoumustaddanin-line
fuse/breakertothepositivewireofyourproduct’spowerconnection.
Caution:Powersupplyprotection
Wheninstallingthisproductensurethepowersourceisadequatelyprotectedby
meansofasuitably-ratedfuseorautomaticcircuitbreaker.
P owerdistribution
Recommendationsandbestpractice.
•Theproductissuppliedwithapowercable,eitherasaseparateitemoracaptivecable
permanentlyattachedtotheproduct.Onlyusethepowercablesuppliedwiththeproduct.Do
NOTuseapowercabledesignedfor,orsuppliedwith,adifferentproduct.
Connections33