EasyManua.ls Logo

Raymarine Evolution EV-1 - Grounding - Dedicated Drain Wire Required; Power Distribution - ACU

Raymarine Evolution EV-1
142 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Grounding—Dedicateddrainwirerequired
Thisproductincludesadedicateddrainconductor(screen)forconnectiontoavessel'
sRFground
point.
ItisimportantthataneffectiveRFgroundisconnectedtotheunit.Theunitcanbegroundedby
connectingthedrainconductor(screen)tothevessel'sRFgroundpoint.OnvesselswithoutanRF
groundsystemthedrainconductor(screen)shouldbeconnecteddirectlytothenegativebattery
terminal.
Thedcpowersystemshouldbeeither:
•Negativegrounded,withthenegativebatteryterminalconnectedtothevessel'sground;or
•Floating,withneitherbatteryterminalconnectedtothevessel'sground.
Ifseveralitemsrequiregrounding,theymayfirstbeconnectedtoasinglelocalpoint(e.g.withina
switchpanel),withthispointconnectedviaasingle,appropriately-ratedconductor,tothevessel’s
commonRFgroundpoint.
Implementation
Thepreferredminimumrequirementforthepathtogroundisviaaflattinnedcopperbraid,with
a30Arating(1/4inch)orgreater.Ifthisisnotpossible,anequivalentstrandedwireconductor
maybeused,ratedasfollows:
•forrunsof<1m(3ft),use6mm
2
(#10AWG)orgreater.
•forrunsof>1m(3ft),use8mm
2
(#8AWG)orgreater.
Inanygroundingsystem,alwayskeepthelengthofconnectingbraidorwiresasshortaspossible.
References
•ISO10133/13297
•BMEAcodeofpractice
•NMEA0400
Powerdistribution—ACU
Recommendationsandbestpractice.
•TheproductisNOTsuppliedwithapowercable.PleaserefertothePoweranddrivecables
sectionforpowercablerequirements.
•Refertothe
Powerconnection
sectionformoreinformationonhowtoidentifythewiresinyour
product’spowercable,andwheretoconnectthem.
•Seebelowformoreinformationonimplementationforsomecommonpowerdistributionscenarios.
Important:
Whenplanningandwiring,tak eintoconsiderationotherproductsinyoursystem,someofwhich
(e.g.sonarmodules)mayplacelargepowerdemandpeaksonthevessel’selectricalsystem.
Note:
Theinformationprovidedbelowisforguidanceonly ,tohelpprotectyourproduct.Itcovers
commonvesselpowerarrangements,butdoesNOTcovereveryscenario.Ifyouareunsurehow
toprovidethecorrectlevelofprotection,pleaseconsultanauthorizedRaymarinedealerora
suitablyqualifiedprofessionalmarineelectrician.
Implementation—directconnectiontobattery
•Theunitmaybeconnecteddirectlytothevessel' sbattery,viaasuitablyratedfuseorbreaker.
•TheunitalsorequiresaseparateRFGround(drain)connection,refertothefollowingsection:
Grounding—Dedicateddrainwirerequired
.
•YouMUSTfitasuitably-ratedfuseorbreakerbetweentheredwireandthebattery’spositive
terminal.ThisisrequiredinadditiontotheinternalfusefittedtotheACU.
•Refertothetablebelowforsuitablefuseratings.
A CU-200,ACU-300,ACU-400connections
89