AngleDistanceAngleDistance
0°
18.5mm(0
.73in)
13°
12.1mm(0.48in)
1°
18.0mm(0
.71in))
14°
11.6mm(0.47in)
2°
17
.5mm(0.69in)
15°
11.1mm(0.44in)
3°
17
.1mm(0.67in)
16°
10.6mm(0.42in)
4°
16.6mm(0
.65in)
17°
10.0mm(0.40in)
5°
16.
1mm(0.63in)
18°
9.5mm(0.37in)
6°
15.6mm(0 .61in)
19°
9.0mm(0.35in)
7°
15. 1mm(0.59in)
20°
8.4mm(0.33in)
8°
14.6mm(0 .57in)
21°
7.9mm(0.31in)
9°
14. 1mm(0.56in)
22°
7.3mm(0.29in)
10°
13.6mm(0 .54in)
23°
6.8mm(0.27in)
11°
13. 1mm(0.52in)
24°
6.2mm(0.24in)
12°
12.6mm(0 .50in)
25°
5.6mm(0.22in)
Mountingthetransducer
Thetransducershouldbemountedfollowingthestepsbelow .
Important:
•Onlyperformtheinstallationwithyourvesseloutofthewater .
•DoNOTliftorsuspendthetransducerusingitscable.
•Ensurethatthetransducerbodyissupportedduringinstallation.
•DoNOTremovethelabelattachedtothetransducercable,asithelpstoensurecorrect
connection.
•DoNOTovertightenthehullnutoranti-rotationbolt.Overtighteningcancausedamagetothe
hulland/ortransducerwhichmayresultinwaterleakingintothevessel.
32