66 RayPilot 650 Control Unit - Owners Handbook
6 Adjusting Autopilot Settings
6.2 Type 100/300 course computers
Accessing Calibration mode
You can only access Calibration mode from Standby mode:
1. With the autopilot in Standby mode, press and hold
STBY for
16 seconds until the display shows a small
CAL legend.
2. Press
AUTO and STBY together to enter Calibration mode.
3. Press
AUTO to scroll through the various calibration screens.
4. When you reach an item you wish to adjust, use the
(NAV) and
(LIGHTS) keys or course change knob to change the value.
5. When you have made all the required changes, press and hold
STBY for 2 seconds to exit Calibration mode and save changes.
Note: To exit Calibration mode without saving changes, press
STBY
momentarily.
Calibration screens
When you use the RayPilot 650 with a Type 100/300 course
computer, the calibration screens appear in the following order:
Vessel type (vES tYP)
Vessel type should be set when commissioning the autopilot.
Note: When you select the vessel type, the autopilot will set
appropriate defaults for several other calibration settings.
Options
1Displacement
2 Semi-displacement
3 Planing
4 Boat with I/O drive (stern drive)