Chapter 6: Adjusting Tiller Pilot Settings 61
Calibration features
The number on the left identifies the calibration feature and the number on
the right the currently selected value.
You can enter the calibration menu to view the existing values without alter-
ing them. After viewing the value, a momentary press of
standby returns the
pilot to its normal operating mode without affecting the previous settings.
If the display shows CAL OFF when you try to enter calibration, refer to
page
64
.
Default calibration values
The following table shows the default calibration values. These will provide safe
performance for initial sea trial.
No. Feature Default setting Adjusted values
1 Rudder gain 5
5 Average cruise speed 8
6 Off course alarm angle 20
9 Local magnetic variation Off (– –)
10 North/South turning error
correction
Off (0)
11 Boat’s current latitude 0
13 Rudder damping 3
Calibration feature Value
D167-07a
D214-1
81130_5.book Page 61 Wednesday, June 15, 2005 3:48 PM