Chapter 6: Adjusting Tiller Pilot Settings 61
Calibration features
• The number on the left identifies the calibration feature and the number on
the right the currently selected value.
• You can enter the calibration menu to view the existing values without alter-
ing them. After viewing the value, a momentary press of
standby returns the
pilot to its normal operating mode without affecting the previous settings.
• If the display shows CAL OFF when you try to enter calibration, refer to
page
64
.
Default calibration values
The following table shows the default calibration values. These will provide safe
performance for initial sea trial.
No. Feature Default setting Adjusted values
1 Rudder gain 5
5 Average cruise speed 8
6 Off course alarm angle 20
9 Local magnetic variation Off (– –)
10 North/South turning error
correction
Off (0)
11 Boat’s current latitude 0
13 Rudder damping 3
Calibration feature Value
D167-07a
D214-1
81130_5.book Page 61 Wednesday, June 15, 2005 3:48 PM