Chapter 4: Customising the System
43
Setting Description
DISPLACE Displacement
SEMI/ DISPLACE Semi-displacement
PLANING Planing
STERN DRV Sterndrive
Default: DISPLACE
Calibration Lock
Calibration lock controls the access to User Setup, and is intended for
charter boat users.
Setting Description
ON User setup locked
OFF User setup unlocked
Default: OFF
Rudder Gain
This must be set while under way, as described in Chapter 6, Post
Installation Procedures.
Range: 1 to 9
Default: for Pilot Type Displacement 5
for Pilot Type Semi-Displacement 5
for Pilot Type Planing 4
for Pilot Type Stern drive 3
Rate Level
Rate Level applies rudder to reduce the rate of change of course. If the
vessel is turning at too fast a rate, the rate level will counter this turn
with opposite rudder.