CONTENTS
Preparation . . . . . . . . . . . . . . . .2-5
Assembly . . . . . . . . . . . . . . . . . . 6
Installation . . . . . . . . . . . . . . . 7-14
Install the Door Control. . . . . . 15-16
Install the Protector System
®
. . 17-20
Power. . . . . . . . . . . . . . . . . . 21-22
Adjustments . . . . . . . . . . . . . 23-25
Operation . . . . . . . . . . . . . . . 26-32
Maintenance . . . . . . . . . . . . . 33-34
Troubleshooting. . . . . . . . . . . 35-36
Accessories. . . . . . . . . . . . . . . . 37
Warranty. . . . . . . . . . . . . . . . . . 38
Automatic Garage Door Opener
Safety & Maintenance Guide . . 39-40
Repair Parts . . . . . . . . . . . . . 41-42
STANDARD Series
1/2 hp Chain Drive
Wi-Fi
®
Garage Door
Opener
Raynor Garage Doors
1101 E. River Rd.
Dixon, Illinois 61021
Please read this manual and the enclosed safety materials carefully!
Fasten the manual near the garage door after installation.
The door WILL NOT CLOSE unless the Protector System
®
is connected and properly
aligned.
Periodic checks of the garage door opener are required to ensure safe operation.
The model number label is located on the front panel of your garage door opener.
This garage door opener is ONLY compatible with MyQ
®
Security+ 2.0
®
accessories.
ONLY enable the Timer-to-Close or MyQ remote operation feature when the garage
door opener is installed on a sectional door.
NOTE: If you are installing the garage door opener on a one-piece door, visit
www.raynor.com for installation instructions.
www.raynor.com
Model 8165WRGD
FOR RESIDENTIAL USE ONLY
SERIAL NUMBER:
Please write the MyQ Serial number in the box above. See page 2.
Register online at: http://blog.raynor.com/warranty-registration
Question and Answer IconNeed help?

Do you have a question about the Raynor CORPORAL II STANDARD Series and is the answer not in the manual?

Raynor CORPORAL II STANDARD Series Specifications

General IconGeneral
Horsepower1/2 HP
Drive TypeChain Drive
Voltage120V
Speed7 inches per second
Remote Controls Included2
Battery BackupNo

Summary

Preparation

myQ® Serial Number and Safety Review

Record serial number and understand safety symbols and signal words for hazard awareness.

Smartphone Connectivity and Door Check

Prepare for smartphone use and check garage door balance and operation.

Tools Needed and Carton Inventory

List of required tools and components included in the package.

Assembly

Attach Rail and Tighten Chain

Connect the rail to the opener and adjust the chain tension for proper operation.

Installation

Important Installation Instructions

Essential warnings and guidelines for safe and correct installation.

Header Bracket and Rail Installation

Determine location, install header bracket, and attach rail.

Opener Positioning and Mounting

Position the opener and hang it securely using appropriate brackets.

Component Installation (Lights, Rope, Door Bracket)

Install light bulbs, attach release rope, and mount the door bracket.

Door Arm Connection

Connect the door arm to the opener trolley.

Install the Door Control

Door Control Panel Installation

Mount the control panel on the wall and connect its basic wiring.

Wire Control to Opener and Attach Labels

Connect control wiring to the opener and affix safety warning labels.

Install the Protector System®

Safety Sensor Installation Guide

Understand the system and install the safety reversing sensors.

Wire and Align Safety Reversing Sensors

Connect sensor wiring to the opener and ensure correct alignment.

Power

Connecting Power and Aligning Sensors

Connect the opener to power and align the safety reversing sensors.

Adjustments

Program Travel Limits and Force

Set door travel limits and configure force sensitivity for safe operation.

Test Safety Reversal and Sensor Systems

Verify the proper functioning of safety reversal and sensor systems.

Operation

Important Safety Instructions

Key safety guidelines for operating the garage door opener safely.

Opener Features and Smartphone Connectivity

Overview of features like Alert2Close, Timer-to-Close, and myQ connectivity.

Using Controls and Programming Remotes

Operate with door control, program remotes, and set panel features.

Memory Management and Manual Operation

Erase memory, manage Wi-Fi settings, and open the door manually.

Maintenance

Maintenance Schedule

Recommended monthly, yearly, and bi-yearly maintenance tasks.

Remote Control Battery Replacement

Instructions for replacing the battery in the remote control.

Troubleshooting

Diagnostic Chart and Error Codes

Troubleshoot issues using diagnostic codes, symptoms, and solutions.

Connectivity and Operation Troubleshooting

Resolve Wi-Fi, remote, and door movement issues.

Accessories

Compatible Accessories List

List of compatible remote controls, keyless entry, and other accessories.

Warranty

Raynor Limited Warranty Information

Details of the product's limited warranty period and coverage.

Automatic Garage Door Opener Safety & Maintenance Guide

Garage Door Opener Safety Guidelines

Important safety information for preventing entrapment and injury.

Routine Maintenance and Testing

Tips for regular inspection and testing of the door and opener.

Repair Parts

Rail Assembly and Installation Parts

Lists parts for rail assembly and installation components.

Garage Door Opener Internal Parts

Lists internal components and panels for the opener.