Detector Type | Solid-state detector |
---|---|
kVp Range | 40 kVp to 150 kVp |
Accuracy | ±5% |
Measurement Parameters | dose, dose rate, kVp |
Display | Color touchscreen |
Communication | Bluetooth, USB |
Power Supply | Rechargeable battery |
Application | X-ray quality assurance |
Dose Rate Range | 0.1 µGy/s to 100 mGy/s |
Time Range | 0.1 ms to 999 s |
Battery Life | 8 hours |
Storage Temperature | -10°C to 50°C |
Weight | 1.5 kg |
Overview of the RaySafe X2 system components: base unit, sensors, and software.
Explains how to use the base unit's touch screen and buttons for navigation.
Details on how to view recorded measurements and their specifications on the base unit.
Instructions for accessing previously saved measurements via the base unit or X2 View software.
How to customize the display of measured parameters on the home screen.
Guide to viewing and analyzing waveform data for measurements.
Steps for connecting the base unit to a computer using a USB cable and X2 View.
Instructions for establishing a wireless connection between the base unit and a computer via Bluetooth.
Procedure for updating the base unit software using a connected computer and internet.
How to charge the base unit battery using the provided power supply.
Examples and guidance on using the flexi stand for sensor positioning.
Instructions for adjusting the screen brightness to prolong battery life.
How to adjust the speaker volume, from off (0%) to maximum (100%).
Procedure for setting the local time and date for accurate measurement logging.
Information regarding the proper disposal of the system according to environmental regulations.
Details on regulatory compliance marks and certifications for the device.
Instructions for positioning and exposing with the R/F sensor for measurements.
Defines parameters like Dose rate, kVp, and total filtration for R/F sensor measurements.
Details technical specifications for the R/F sensor, including dimensions, weight, and operating conditions.
Selects the displayed units for dose and dose rate measurements for the R/F sensor.
Configures the time the instrument waits for more radiation to include in the same measurement.
Removes unwanted prepulses from the measurement by setting the ignore prepulses value.
Instructions for positioning the MAM sensor for dose and HVL measurements.
Instructions for measuring Mo/Rh kV using the MAM sensor with an Al filter.
Procedure for W/Al scanning with the MAM sensor, including settings for different systems.
Defines parameters like Dose rate, kVp, and HVL for MAM sensor measurements.
Details technical specifications for the MAM sensor, including dimensions, weight, and operating conditions.
Selects beam quality for kVp readings with the MAM sensor.
Selects the displayed units for dose and dose rate measurements for the MAM sensor.
Configures the time the instrument waits for more radiation to include in the same measurement.
Removes unwanted prepulses from the measurement by setting the ignore prepulses value.
Instructions for positioning the CT sensor in a phantom or free air.
Instructions for measuring kVp on CT using an R/F sensor.
Defines parameters like Dose, Dose rate, and Dose length product for CT sensor measurements.
Details technical specifications for the CT sensor, including dimensions, weight, and operating conditions.
Selects the displayed units for dose and dose rate measurements for the CT sensor.
Configures the time the instrument waits for more radiation to include in the same measurement.
Instructions for measuring luminance and illuminance with the Light sensor.
Defines Illuminance as light incident on a surface and Luminance as light emitted from a surface.
Details technical specifications for the Light sensor, including dimensions, weight, and operating conditions.
Selects units for luminance (cd/m², fL) and illuminance (lux, fc).
Instructions for positioning and measuring with the Survey sensor.
Procedure for performing zero adjustment or resetting to factory zero for the Survey sensor.
Defines Time, Dose, Dose rate, and Mean energy parameters for Survey sensor measurements.
Details technical specifications for the Survey sensor, including dimensions, weight, and angular deviation.
Configures measurement triggering and displayed parameters for the Survey sensor.
Selects displayed units for Air kerma (Gy/R) and Ambient dose equivalent (Sv).
Configures the time the instrument waits for more radiation to include in the same measurement.
Instructions for connecting the mAs cable and performing mAs measurements.
Defines mAs, mA, Time, and Pulses parameters for mAs measurements.
Configures the time the instrument waits for more radiation to include in the same measurement.
Removes unwanted prepulses from the measurement by setting the ignore prepulses value.